Error Messages of N6 (P6) (LED Display)

When an error occurs, the integrated MCU issues an LED error message which gives more detailed information on the kind of error. As soon as the error LED is illuminated permanently, the LEDs OK, INPUT, and PWR lose their normal functions and show an error code. Please note this error code down and inform the noax service department.


Description ERROR LED OK LED INPUT LED PWR LED
Reference voltage faulty on off off on
MCU-IRAM faulty on off off off
MCU-IRAM faulty on off off flashes
MCU-ROM faulty on off on off
MCU-XRAM faulty on off on on
Input voltage at IPC too high 1) on off on flashes
Input voltage at IPC too low 1) on off flashes off
Internal system temperature too high 2) on off flashes flashes
Internal system temperature too low 2) on on off off
Fan failure on on off flashes
CPU core voltage faulty on on on off
GTL termination voltage faulty on on on on
CPU clock voltage faulty on on on flashes
3.3 V power supply faulty on on flashes off
5V power supply faulty on on flashes on
12V power supply faulty on on flashes flashes
12V-anticipatory voltage control faulty on flashes off off

  • 12V power supply faulty

on flashes off on
Default setup is being used off flashes irrelevant irrelevant
System in temperature limitation flashes irrelevant irrelevant irrelevant


1) Input voltage too high / too low:
As soon as the unit is supplied with power, the input voltage is monitored. If this is already faulty at this stage, the unit cannot be switched on. In this case, please check the external desk power supply or the electric circuit that supplies the unit with power. If the input voltage exceeds the normal range during operation, the unit will turn itself off, too.

2) Internal system temperature too high / too low:
If the internal system temperature is too low, the unit cannot be switched on, or it automatically switches off to prevent waterdrops forming inside the unit (dew protection). If the internal system temperature is too high, the unit cannot be switched on, either. If the temperature rises too high during operation, the unit will first switch to another mode of operation with the least possible heat generation. For this, the backlight is dimmed, amongst others. This mode of operation is indicated bya flashing ERROR-LED zu erkennen. If this occurs, please check if there is sufficient air circulation at the corrugated rear panel and make sure that the unit is not covered by objects. After the temperature has fallen again, the unit automatically switches back to normal operation; however, should the temperature keep rising, the unit switches off completely and can only be switched on again after suffcient cooling down.


Special cases:

  1. ERROR LED flashes: The internal temperature of the unit is too high; if it rises any further, the unit will be switched off. At this stage, the backlight will be dimmed permanently to lower heat-buildup.
  2. OK LED flashes, ERROR LED off:]] The unit utilizes standard settings for MCU Setup, because the default jumper is set.