DC/DC Converter 18-60 V - Input Fuse Fails Regularly
Regarding DC/DC converter part no. 11172 in mobile
forklift operation
If the DC/DC converter part no. 11172 is used in mobile
applications such as forklifts, depending on the type of
forklift this can result in recurring failure of the input
fuse protection of the power supply . This is caused
by return currents from the converter due to
voltage fluctuations in the forklift's power supply.
Should this problem occur, the DC/DC converter can be sent
to noax for modification. Please contact the
noax hotline
for this purpose.
|